Study of hybrid geothermal cooling system

Author: 
A. Nagy Elsayed, M. M. Abo El Nasr and W. Aboelsoud
Subject Area: 
Physical Sciences and Engineering
Abstract: 

Using renewable energy for heating and cooling applications covers the increasing demand of energy sources. In the present study, numerical analysis is used to study 9 closed-loop geothermal air pipe system cases during summer and winter with different pipe geometry of diameters of 0.17, 0.35, and 0.65 meters and total pipe lengths of 47, 64 & 87 meters for air conditioning application. The conditioned air is then supplied to a room of Length 3m x Width 3m x Height 3m. The numerical model is combined with a 1 m length solar chimney of 45ᵒ inclination angle. Also, an experiment was conducted in Damanhur city, Beheira Governorate, Egypt, providing conditioned air to a room of L 2m x W 2m x H 2m via a 5 m long, 5.3 mm thick geothermal PVC air pipe of 2 inches in diameter. The pipe was buried at 2 m depth and was supported by the solar chimney during winter to provide natural draft force inside the closed-loop system and to support the heating process. On the other hand, the closed loop contains a driving fan to provide circulation during summer. The results of the numerical model prove that the numerical analysis showed the highest level of air conditioning temperature difference close to 5 ᵒC for the case of 0.65 m diameter pipe, and 87 m total length. The validation of the numerical model was carried out using experimental results.

PDF file: 

CALL FOR PAPERS

 

ONLINE PAYPAL PAYMENT

IJMCE RECOMMENDATION

Advantages of IJCR

  • Rapid Publishing
  • Professional publishing practices
  • Indexing in leading database
  • High level of citation
  • High Qualitiy reader base
  • High level author suport

Plagiarism Detection

IJCR is following an instant policy on rejection those received papers with plagiarism rate of more than 20%. So, All of authors and contributors must check their papers before submission to making assurance of following our anti-plagiarism policies.

 

EDITORIAL BOARD

Dr. Swamy KRM
India
Dr. Abdul Hannan A.M.S
Saudi Arabia.
Luai Farhan Zghair
Iraq
Hasan Ali Abed Al-Zu’bi
Jordanian
Fredrick OJIJA
Tanzanian
Firuza M. Tursunkhodjaeva
Uzbekistan
Faraz Ahmed Farooqi
Saudi Arabia
Eric Randy Reyes Politud
Philippines
Elsadig Gasoom FadelAlla Elbashir
Sudan
Eapen, Asha Sarah
United State
Dr.Arun Kumar A
India
Dr. Zafar Iqbal
Pakistan
Dr. SHAHERA S.PATEL
India
Dr. Ruchika Khanna
India
Dr. Recep TAS
Turkey
Dr. Rasha Ali Eldeeb
Egypt
Dr. Pralhad Kanhaiyalal Rahangdale
India
DR. PATRICK D. CERNA
Philippines
Dr. Nicolas Padilla- Raygoza
Mexico
Dr. Mustafa Y. G. Younis
Libiya
Dr. Muhammad shoaib Ahmedani
Saudi Arabia
DR. MUHAMMAD ISMAIL MOHMAND
United State
DR. MAHESH SHIVAJI CHAVAN
India
DR. M. ARUNA
India
Dr. Lim Gee Nee
Malaysia
Dr. Jatinder Pal Singh Chawla
India
DR. IRAM BOKHARI
Pakistan
Dr. FARHAT NAZ RAHMAN
Pakistan
Dr. Devendra kumar Gupta
India
Dr. ASHWANI KUMAR DUBEY
India
Dr. Ali Seidi
Iran
Dr. Achmad Choerudin
Indonesia
Dr Ashok Kumar Verma
India
Thi Mong Diep NGUYEN
France
Dr. Muhammad Akram
Pakistan
Dr. Imran Azad
Oman
Dr. Meenakshi Malik
India
Aseel Hadi Hamzah
Iraq
Anam Bhatti
Malaysia
Md. Amir Hossain
Bangladesh
Ahmet İPEKÇİ
Turkey
Mirzadi Gohari
Iran