CERTIFICATE

IMPACT FACTOR 2021

Subject Area

  • Life Sciences / Biology
  • Architecture / Building Management
  • Asian Studies
  • Business & Management
  • Chemistry
  • Computer Science
  • Economics & Finance
  • Engineering / Acoustics
  • Environmental Science
  • Agricultural Sciences
  • Pharmaceutical Sciences
  • General Sciences
  • Materials Science
  • Mathematics
  • Medicine
  • Nanotechnology & Nanoscience
  • Nonlinear Science
  • Chaos & Dynamical Systems
  • Physics
  • Social Sciences & Humanities

Why Us? >>

  • Open Access
  • Peer Reviewed
  • Rapid Publication
  • Life time hosting
  • Free promotion service
  • Free indexing service
  • More citations
  • Search engine friendly

Cadmium, lead, arsenic and mercury levels in earthenware clay deposits atvume, in the South Tongu district of Ghana, using atomic absorption spectrophotometric technique

Author: 
Samlafo, B. V., Bobobee, L. H., Quarshie, E. and Sarsah, L. A.
Subject Area: 
Physical Sciences and Engineering
Abstract: 

This paper screened for potentially harmful heavy metals such as As, Pb, Cd and Hg in earthenware clay deposits at Vume in the Volta region of Ghana using Atomic Absorption Spectrophotometric (AAS) technique. The concentrations of As in the clay samples ranged from 0.90µg/g to 2.04 µg/g with a mean of 1.49 µg/g, and standard deviation of 0.47. Lead levels ranged from 2.85 µg/g to 4.08 µg/g with a mean of 3.67µg/g, and a standard deviation of 0.38. Cadmium was below the detection limit of 0.002 µg/g in some samples: however, the levels measured ranged from 0.15 µg/g to 0.51 µg/g with a mean of 0.29 µg/g, and a standard deviation of 0.13. The concentrations of mercury ranged from 0.18 µg/g to 0.69 µg/g with a mean of 0.53 µg/g, and a standard deviation of 0.15. The levels of Hg,Cd and Pb fell below their respective US EPA(1990) safe levels of 18.0 µg/g, 1.7 µg/g and 80.0 µg/g, except that of As which was above its US EPA(1990) safe level of 0.07 µg/g.The levels of Arsenic in the study area, though higher than the US EPA safe level, were comparable to the worldwide background level of 5 µg/g in soil. The precision and the accuracy of the AAS method were assessed via the use of reference material IAEA Soil-7. The values obtained for the various elements in the standard reference material (by analysing it with the AAS method) compared favourably well with the recommended values as Spearman’s correlation coefficient was + 0.96. The experimental values were within ±5% of the recommended value. The measurement precision determined by the relative standard deviation was within ±4%. With the exception of As levels which need some remediation, the quality of the clay at Vume was found to be generally good for the production of earthenware products.

PDF file: 

ONLINE PAYPAL PAYMENT

IJMCE RECOMMENDATION

Advantages of IJCR

  • Rapid Publishing
  • Professional publishing practices
  • Indexing in leading database
  • High level of citation
  • High Qualitiy reader base
  • High level author suport

Plagiarism Detection

IJCR is following an instant policy on rejection those received papers with plagiarism rate of more than 20%. So, All of authors and contributors must check their papers before submission to making assurance of following our anti-plagiarism policies.

 

EDITORIAL BOARD

Dr. Swamy KRM
India
Dr. Abdul Hannan A.M.S
Saudi Arabia.
Luai Farhan Zghair
Iraq
Hasan Ali Abed Al-Zu’bi
Jordanian
Fredrick OJIJA
Tanzanian
Firuza M. Tursunkhodjaeva
Uzbekistan
Faraz Ahmed Farooqi
Saudi Arabia
Eric Randy Reyes Politud
Philippines
Elsadig Gasoom FadelAlla Elbashir
Sudan
Eapen, Asha Sarah
United State
Dr.Arun Kumar A
India
Dr. Zafar Iqbal
Pakistan
Dr. SHAHERA S.PATEL
India
Dr. Ruchika Khanna
India
Dr. Recep TAS
Turkey
Dr. Rasha Ali Eldeeb
Egypt
Dr. Pralhad Kanhaiyalal Rahangdale
India
DR. PATRICK D. CERNA
Philippines
Dr. Nicolas Padilla- Raygoza
Mexico
Dr. Mustafa Y. G. Younis
Libiya
Dr. Muhammad shoaib Ahmedani
Saudi Arabia
DR. MUHAMMAD ISMAIL MOHMAND
United State
DR. MAHESH SHIVAJI CHAVAN
India
DR. M. ARUNA
India
Dr. Lim Gee Nee
Malaysia
Dr. Jatinder Pal Singh Chawla
India
DR. IRAM BOKHARI
Pakistan
Dr. FARHAT NAZ RAHMAN
Pakistan
Dr. Devendra kumar Gupta
India
Dr. ASHWANI KUMAR DUBEY
India
Dr. Ali Seidi
Iran
Dr. Achmad Choerudin
Indonesia
Dr Ashok Kumar Verma
India
Thi Mong Diep NGUYEN
France
Dr. Muhammad Akram
Pakistan
Dr. Imran Azad
Oman
Dr. Meenakshi Malik
India
Aseel Hadi Hamzah
Iraq
Anam Bhatti
Malaysia
Md. Amir Hossain
Bangladesh
Ahmet İPEKÇİ
Turkey
Mirzadi Gohari
Iran