Clinical safety and performance of a novel ultra-thin strut cobalt-chromium bare metal stent implanted in real-world patients with coronary artery disease

Author: 
Dr. Mahesh Basarge, Dr. Parvindar Singh and Dr. Ashok Thakkar
Subject Area: 
Health Sciences
Abstract: 

Background: Despite the prevalent use of drug-eluting stents (DES) in current clinical scenario, many coronary artery disease (CAD) patients are still treated with bare-metal stents (BMS). Aim: The purpose of this registry was to assess the clinical performance and safety of the ultra-thin (65 μm) strut cobalt-chromium Osum™ BMS for the intervention of CAD patients in real-world clinical practice. Materials and Methods: This was an observational, non-randomized, retrospective, single-arm registry with a target of evaluating safety and performance of 467 consecutive patients who underwent treatment for CAD by Osum stent implantation from January 2012 to October 2016. The mean follow-up duration of this study was 2 years. The endpoint of the study was to observe major adverse cardiac events (MACE), which includes myocardial infarction (MI), cardiac death, and ischemia-driven target lesion revascularization (ID-TLR). Results: A total of 512 lesions were treated in 467 enrolled patients (mean age: 56.57 ± 11.02 years) with 28.12 ± 7.89 mm average stent length and average stent diameter of 2.88 ± 0.40 mm. An average of 1.08 ± 0.27 study stent was implanted per patient. Out of 467 patients, 370 (79.23%) were males, 119 (25.48%) were diabetics and 206 (44.11%) had hypertension. At 2.0 ± 1.5 years follow-up, the total incidence of MACE occurred in 36 (7.71%) patients which include 2 (0.43%) MI, 30 (6.42%) cardiac deaths and 4 (0.86%) ID-TLR. There were no cases of stent thrombosis (ST). Conclusions: This study demonstrated that Osum BMS is associated with a low rate of major adverse cardiac events with an absence of stent thrombosis at a mean follow-up of 2 years in real-world coronary artery disease patients. Trial registration: This study is registered at clinical trial registry of India with CTRI number: CTRI/2017/11/010531

PDF file: 

ONLINE PAYPAL PAYMENT

IJMCE RECOMMENDATION

Advantages of IJCR

  • Rapid Publishing
  • Professional publishing practices
  • Indexing in leading database
  • High level of citation
  • High Qualitiy reader base
  • High level author suport

Plagiarism Detection

IJCR is following an instant policy on rejection those received papers with plagiarism rate of more than 20%. So, All of authors and contributors must check their papers before submission to making assurance of following our anti-plagiarism policies.

 

EDITORIAL BOARD

Dr. Swamy KRM
India
Dr. Abdul Hannan A.M.S
Saudi Arabia.
Luai Farhan Zghair
Iraq
Hasan Ali Abed Al-Zu’bi
Jordanian
Fredrick OJIJA
Tanzanian
Firuza M. Tursunkhodjaeva
Uzbekistan
Faraz Ahmed Farooqi
Saudi Arabia
Eric Randy Reyes Politud
Philippines
Elsadig Gasoom FadelAlla Elbashir
Sudan
Eapen, Asha Sarah
United State
Dr.Arun Kumar A
India
Dr. Zafar Iqbal
Pakistan
Dr. SHAHERA S.PATEL
India
Dr. Ruchika Khanna
India
Dr. Recep TAS
Turkey
Dr. Rasha Ali Eldeeb
Egypt
Dr. Pralhad Kanhaiyalal Rahangdale
India
DR. PATRICK D. CERNA
Philippines
Dr. Nicolas Padilla- Raygoza
Mexico
Dr. Mustafa Y. G. Younis
Libiya
Dr. Muhammad shoaib Ahmedani
Saudi Arabia
DR. MUHAMMAD ISMAIL MOHMAND
United State
DR. MAHESH SHIVAJI CHAVAN
India
DR. M. ARUNA
India
Dr. Lim Gee Nee
Malaysia
Dr. Jatinder Pal Singh Chawla
India
DR. IRAM BOKHARI
Pakistan
Dr. FARHAT NAZ RAHMAN
Pakistan
Dr. Devendra kumar Gupta
India
Dr. ASHWANI KUMAR DUBEY
India
Dr. Ali Seidi
Iran
Dr. Achmad Choerudin
Indonesia
Dr Ashok Kumar Verma
India
Thi Mong Diep NGUYEN
France
Dr. Muhammad Akram
Pakistan
Dr. Imran Azad
Oman
Dr. Meenakshi Malik
India
Aseel Hadi Hamzah
Iraq
Anam Bhatti
Malaysia
Md. Amir Hossain
Bangladesh
Ahmet İPEKÇİ
Turkey
Mirzadi Gohari
Iran